Pressure taps give a wind tunnel model a few hundred pressure readings at best. Pressure-sensitive paint (PSP) gives a pressure value for every pixel the camera can see. That is why aerodynamic test teams use it to map loads on aircraft, missile and launch-vehicle models, and why the camera is one of the most important parts of a PSP system.
This post is for wind tunnel engineers, aerodynamic test groups and builders of PSP measurement systems. It covers what intensity-based PSP asks of a camera, using Finger Lakes Instrumentation (FLI) Aurora, Revelation and Kepler cameras as examples. Fast unsteady PSP and lifetime-based PSP use high-speed or gated cameras and are outside the scope of this post.
A PSP coating contains luminescent molecules held in an oxygen-permeable binder. Light at the excitation wavelength makes the coating glow, and oxygen in the air quenches that glow. Higher pressure means more oxygen and less light. A review in the Annual Review of Fluid Mechanics (Bell et al., 2001) covers the chemistry, hardware and error sources in depth.
In practice, the camera records a "wind-off" reference image with the tunnel at rest and a "wind-on" image during the run. Dividing one by the other cancels uneven lighting, paint thickness and dye concentration. A Stern-Volmer calibration, usually tied to pressure taps on the model, converts the ratio to pressure. Temperature changes the paint's response, so most programs correct for it, sometimes with a companion temperature-sensitive paint.
Because pressure arrives as a small change in brightness, the camera's job is to measure brightness very precisely. In a well-lit PSP image, photon shot noise dominates, so the precision of each pixel depends mainly on how many electrons it collects.
Aurora and Revelation cameras list a 50,000 e- full well and 1 e- rolling read noise. At half of full well, 25,000 e-, shot noise gives a signal-to-noise ratio of about 158 to 1. A ratio of two such images carries about 0.9% noise per pixel. Averaging 16 wind-on and 16 wind-off frames brings that to about 0.22%. Summing 2 × 2 pixels in software halves it again, at the cost of resolution, an approach also studied for unsteady PSP (AIAA AVIATION, 2021). These figures are illustrative arithmetic; your paint, lighting and exposure set the real ones.
Low-speed testing is where this matters most. The pressure differences are small, so the brightness changes are small, and the averaging budget grows. Binning on these Sony sensors is digital, so it does not lower read noise, but in a shot-noise-limited image that matters little. Cooling keeps dark current from eating into long averaging runs; Aurora and Revelation cool to about 50 °C below ambient on air, with liquid cooling as an option. See our post on long-exposure dark current.
The ratio method assumes the camera's output is proportional to light. If the response bends, the ratio shifts, and the pressure map inherits the error. The PSP literature notes that a camera with a non-linear response needs a radiometric calibration before the ratio is taken.
Kepler cameras produce a 16-bit high dynamic range image from two 12-bit readouts at different gains, with less than 1% non-linearity. That wide range also helps when one image includes both a brightly lit wing root and a dim trailing edge. Check gain, noise and linearity on each unit you receive; our post on camera acceptance testing shows how. Data-sheet values are typical, and FLI provides a production test summary for each camera by serial number.
Common platinum-porphyrin paints are excited in the near UV or blue and emit near 650 nm. One published setup used 390 nm peak excitation, 650 nm peak emission and a 650 ± 10 nm band-pass filter. The filter must block the excitation light thoroughly, because any leak adds a pressure-independent signal to every pixel. Compare quantum efficiency curves in your emission band rather than headline peak figures.
Some paints add a second, pressure-insensitive reference luminophore that emits in a different band, so the camera images the model through two filters. The FLI High Speed Filter Wheel moves to the adjacent filter in 23 ms on the 6-position model and 30 ms on the 10-position model. See our post on fast filter switching.
Take dark frames with the excitation lights off and subtract them from both the wind-off and wind-on images, and repeat them if the camera temperature or exposure changes.
Under load, the model bends, twists and moves, so the wind-on image no longer lines up with the wind-off image. Registration software uses fiducial markers painted on the model to re-align them. Misregistration errors are worst exactly where engineers care most: near shocks, transition and separation.
More pixels across the model help on both counts. Markers span more pixels, so they can be located more precisely, and there is room to bin for noise while still resolving sharp pressure gradients. The AR455 offers 9568 × 6380 pixels on a 36 × 24 mm sensor. The KL6060FI offers 6144 × 6144 pixels at 10 µm for larger image fields. For pixel and lens matching, see our post on pixel size and sampling.
These Sony sensors support global reset with rolling readout. Every row starts exposing at the same moment, and the rows are read out one after another. With steady excitation, that has no effect on a time-averaged image. With pulsed LEDs, time each pulse to end before readout begins, and every row sees the same light. External trigger in and out are standard, so the camera can follow the tunnel's timing controller.
Full coverage of a model usually takes several cameras looking through different windows, each mapped onto the model's surface grid. Our post on synchronizing multiple cooled cameras covers triggering. Where camera ports are cramped, the RV571 puts a 6244 × 4168 sensor into Revelation's thin, fin-less body, and every Revelation camera includes our software development kit. The Kepler SDK supports Windows and Linux.
PSP data feeds loads and performance decisions on defense aircraft and missile programs, so the test equipment brings supplier paperwork. FLI operates under AS9100D / ISO 9001:2015 · ITAR compliant · CMMC Level 2 compliant. We machine housings in-house, finish and test boards, and test every camera before it ships. Our defense camera supplier checklist covers qualification, and our post on test-range optical tracking covers another defense test application.
Send our sales team your paint, lighting, model size and camera positions, and we'll suggest the standard Aurora, Revelation or Kepler configuration that fits your tunnel. Request a quote or email sales@flicamera.com.
FLI cameras are Made in USA, and our sensor chambers are assembled in our 1,000+ sq ft ISO Class 7 clean room. See how on our in-house manufacturing page.